Search results for "Galvanic cell"

showing 10 items of 21 documents

Quantitative and Qualitative in vivo Analysis of Metal Residuals in the Saliva of Subjects with and without Fixed Orthodontic Appliances

2020

Aim of the Work: The aim of this work was to evaluate Ni e Cr ions in the saliva of subjects with and without fixed orthodontic appliances. Materials and Methods: This was a prospective, non-randomized study of 100 patients, so selected: 50 have undergone fixed orthodontic appliance at least from 24 months; others 50 subjects as control-group, without any fixed and/or removable orthodontic appliance It was conducted according to the Declaration of the World Medical Association of Helsinki. The two selected groups were compatible for age, sex, absence of restoration in amalgam or other metals in the oral cavity. The saliva of all the subjects was collected with standardized sterile methods. …

0301 basic medicineSalivaMaterials scienceMetal ions in aqueous solutionfungiMetallurgytechnology industry and agriculture030206 dentistryGeneral MedicineBiocompatible materialCorrosionMetal03 medical and health sciences030104 developmental biology0302 clinical medicineNickel titaniumFixed Orthodontic Appliancevisual_artGalvanic cellvisual_art.visual_art_mediumNickel ionsAtomic Absorption SpectrophotometryMetal IonSaliva
researchProduct

Amorphous Silicon Nanotubes via Galvanic Displacement Deposition

2013

Amorphous silicon nanotubes were grown in a single step into a polycarbonate membrane by a galvanic displacement reaction conducted in aqueous solution. In order to optimize the process, a specifically designed galvanic cell was used. SEM images, after polycarbonate dissolution, showed interconnected nanotube bundles with an average length of 18 μm and wall thickness of 38 nm.The deposited silicon was revealed by EDS analysis, whilst X-ray diffraction and Raman spectroscopy showed that nanotubes have an amorphous structure. Silicon nanotubes were also characterized by photo-electrochemical measurements that showed n-type conductivity and optical gap of ~1.6 eV. Keywords: Silicon nanotubes, …

Amorphous siliconSilicon nanotubes dispalcement deposition nanostructures lithium batteries solar cellsNanotubeMaterials scienceSiliconNanocrystalline siliconchemistry.chemical_elementNanotechnologyAmorphous solidlcsh:Chemistrysymbols.namesakechemistry.chemical_compoundSettore ING-IND/23 - Chimica Fisica Applicatalcsh:Industrial electrochemistrylcsh:QD1-999chemistryvisual_artElectrochemistrysymbolsvisual_art.visual_art_mediumGalvanic cellPolycarbonateComposite materialRaman spectroscopylcsh:TP250-261
researchProduct

Reliability of numerical models for simulating galvanic corrosion processes

2012

International audience; Maturity of numerical simulation represents an important issue in the development of predictive models of galvanic corrosion. As widely used in electrochemical engineering, a coupled electrochemical-transport-reaction (CETR) model is recommended to simulate the current distribution above a galvanic corrosion cell made of the cut-edge of a galvanized steel sheet. Nevertheless, simulating current density distributions obtained experimentally by scanning vibrating electrode technique (SVET) above such a galvanic cell appears to be more accurate using an electrostatic model considering a homogeneous conductivity. In this case, the absence of concentration gradients next …

CUT-EDGESMaterials science020209 energyGeneral Chemical EngineeringINHIBITIONElectrochemical engineering02 engineering and technologySCANNING VIBRATING ELECTRODEsymbols.namesakeZINC0202 electrical engineering electronic engineering information engineeringElectrochemistryGalvanic cellComposite materialSVETComputer simulationIRONMetallurgyDEFECTS021001 nanoscience & nanotechnologyGalvanizationGalvanic corrosionMicroelectrodeElectrodesymbolsCOATED STEEL0210 nano-technologyCurrent density
researchProduct

Galvanic deposition and characterization of brushite/hydroxyapatite coatings on 316L stainless steel

2016

In this work, brushite and brushite/hydroxyapatite (BS, CaHPO4·H2O; HA, Ca10(PO4)6(OH)2) coatings were deposited on 316L stainless steel (316LSS) from a solution containing Ca(NO3)2·4H2O and NH4H2PO4 by a displacement reaction based on a galvanic contact, where zinc acts as sacrificial anode. Driving force for the cementation reaction arises from the difference in the electrochemical standard potentials of two different metallic materials (316LSS and Zn) immersed in an electrolyte, so forming a galvanic contact leading to the deposition of BS/HA on nobler metal. We found that temperature and deposition time affect coating features (morphology, structure, and composition). Deposits were char…

Calcium PhosphatesMaterials scienceGalvanic anodeScanning electron microscopeMaterials ScienceEnergy-dispersive X-ray spectroscopyBioengineering02 engineering and technologyCondensed Matter Physicengineering.material010402 general chemistry01 natural sciencesCorrosionHydroxyapatiteBiomaterialssymbols.namesakeCoatingGalvanic cellBrushiteMechanical EngineeringMetallurgyBiomedical applicationElectrochemical Techniques021001 nanoscience & nanotechnologyStainless Steel0104 chemical sciencesGalvanic depositionDurapatiteSettore ING-IND/23 - Chimica Fisica ApplicataChemical engineeringMechanics of Materialsengineeringsymbols316LSSBrushite0210 nano-technologyRaman spectroscopy
researchProduct

Bioresorbable β-TCP-FeAg nanocomposites for load bearing bone implants: High pressure processing, properties and cell compatibility.

2017

In this paper, the processing and properties of iron-toughened bioresorbable β-tricalcium phosphate (β-TCP) nanocomposites are reported. β-TCP is chemically similar to bone mineral and thus a good candidate material for bioresorbable bone healing devices; however intrinsic brittleness and low bending strength make it unsuitable for use in load-bearing sites. Near fully dense β-TCP-matrix nanocomposites containing 30vol% Fe, with and without addition of silver, were produced employing high energy attrition milling of powders followed by high pressure consolidation/cold sintering at 2.5GPa. In order to increase pure iron's corrosion rate, 10 to 30vol% silver were added to the metal phase. The…

Calcium PhosphatesMaterials scienceSinteringBioengineeringBiocompatible Materials02 engineering and technology010402 general chemistry01 natural sciencesCorrosionNanocompositesBiomaterialsMetalWeight-BearingBrittlenessFlexural strengthAbsorbable ImplantsMaterials TestingGalvanic cellPressureHumansComposite materialchemistry.chemical_classificationNanocompositePolymer021001 nanoscience & nanotechnology0104 chemical scienceschemistryMechanics of Materialsvisual_artvisual_art.visual_art_medium0210 nano-technologyMaterials scienceengineering. C, Materials for biological applications
researchProduct

Earlier Developed Techniques

2014

The first electrochemical experiments were performed with solid materials, esp. metals. However, these experiments, conducted in the eighteenth and nineteenth centuries, were directed toward the elucidation of the basic features of the electrical action of chemical substances and the chemical action of electricity. Initially, metals played the major role; only later it became obvious that many chemical compounds possess metallic or semiconducting properties that can be utilized in electrochemical cells. Parallel to the studies of new electrode materials, solid electrolytes were discovered and entire solid galvanic cells could be constructed. In this book, we will entirely neglect pure solid…

Electrode materialMaterials scienceComposite electrodeGalvanic cellFast ion conductorNanotechnologySolid materialElectrochemistryElectrochemical cell
researchProduct

Partial Discharge on-line measures in cable's EPR insulation

2004

In this paper, an experimental study, carried out on an operating MV cable, is presented. The aim is to identify, locate and characterize defects in the cable's EPR (ethylene-propylene copolymer rubber) insulation. Direct partial discharge measurements have been compared to those obtained by high frequency electromagnetic field measures. The latter have been carried out using a sensor which does not require any galvanic connection with the system under test and that performs an intrinsic localization of the defect. Moreover, an analysis of an MV cable junction has been carried out using the same tools.

Electromagnetic fieldMaterials sciencebusiness.industryAcousticsElectrical engineeringElectrical treeingEthylene propylene rubberLine (electrical engineering)law.inventionpartial dischargeSettore ING-IND/31 - ElettrotecnicaNatural rubberlawvisual_artShielded cablePartial dischargevisual_art.visual_art_mediumGalvanic cellbusiness
researchProduct

Investigation of Different Iontophoretic Currents Profiles for Short-Term Applications in Cosmetics.

2018

[EN] This study aimed at investigating the effect of electrical current profile upon the iontophoretic transport of (i) ascorbic acid (AA) and (ii) ellagic acid (EA), into porcine skin in vitro, and the impact of the physicochemical properties of both actives on their mechanism of transport when formulated in cosmetic compositions. The experiments were performed using a proprietary iontophoretic device containing a roller to apply the formulation. Three current profiles were tested: (i) galvanic direct current (DC), (ii) square unipolar pulse current (SPC), and (iii) galvanic direct current (DC) + pulse current (PC). The skin samples were collected at different sampling points, extracted an…

Ellagic acidMaterials scienceTopical penetrationPharmaceutical Sciencelcsh:RS1-441Galvanic currentSquare unipolar pulse current030226 pharmacology & pharmacyElectromigrationArticlelcsh:Pharmacy and materia medica030207 dermatology & venereal diseases03 medical and health scienceschemistry.chemical_compound0302 clinical medicinetopical penetrationellagic acidgalvanic currentGalvanic cellPulsed currentActive ingredientChromatographyIontophoresisDirect currentsquare unipolar pulse currentPenetration (firestop)IontophoresisiontophoresisAscorbic acidchemistryAscorbic acidascorbic acidpulsed currentEllagic acidPharmaceutics
researchProduct

Evaluation of two oxygen analyzers by computerized data acquisition and processing

1986

Monitoring of inspired oxygen concentration during anesthesia with nitrous oxide is becoming accepted as essential. This type of monitoring demands accurate monitors that respond rapidly. We evaluated two such devices for their response patterns to rapid changes in oxygen concentration, a galvanic or "fuel cell" unit and a polarographic device. Data were stored after analog-to-digital conversion. The response patterns to stepwise changes in nitrous oxide and oxygen mixtures were recorded at flow rates ranging from 2 to 10 L/min. Both units responded accurately to all changes in the absolute oxygen concentration; the polarographic unit was, on average, twice as fast. Responsiveness to nitrou…

Inspired oxygen concentrationComputersNitrous OxideGeneral EngineeringAnalytical chemistrychemistry.chemical_elementResponse timeNitrous oxideAnesthesia GeneralCritical Care and Intensive Care MedicineOxygenVolumetric flow rateOxygenchemistry.chemical_compoundchemistryEvaluation Studies as TopicCalibrationGalvanic cellHumansLimiting oxygen concentrationMonitoring PhysiologicPolarographyJournal of Clinical Monitoring
researchProduct

Online Visualization of Corrosion Processes of Zinc and a Cu/Zn Galvanic Pair in Lithium Bromide Solutions

2003

Abstract A new method has been developed for online visualization of corrosion processes. The system allows surface images of the tested electrode to be captured simultaneously with the recorded electrochemical signal caused by corrosion processes without disturbing the electrochemical system. The experimental device consists of an electrochemical system with a horizontal electrochemical cell coupled to optical equipment. The horizontal position of the electrodes tested permitted the direct observation of surface modifications with time and of the experimental conditions by means of a triocular microscope stereoscope assembled to an image acquisition system. The new methodology was applied …

Lithium bromideGeneral Chemical EngineeringInorganic chemistrychemistry.chemical_elementGeneral ChemistryZincElectrochemistryElectrochemical cellCorrosionGalvanic corrosionchemistry.chemical_compoundchemistryElectrodeGalvanic cellGeneral Materials ScienceCORROSION
researchProduct